Oil settlers (ON)
Oil settler identification for an order and other documents:
- ON–50-1.6-T-I-P-HL1 as per TU 3615-003-22642986-2016,
- where 50 – volume, m3;
- 6 – design pressure, MPa;
- T – heat treatment;
- I – devices fixing heat insulation;
- P – internal anti-corrosion coating;
- HL1 – climatic design.
Parameters and dimensions of equipment
Parameters | Typical dimensions | |||||
---|---|---|---|---|---|---|
ON-12,5 |
ON-25 |
ON-50 |
ON-100 |
ON-150 |
ON-200 |
|
Capacity, m3/day |
500-900 |
1200-1700 |
2500-3500 |
5000-7200 |
7500-10000 |
10000-14400 |
Volume, m3 |
12,5 |
25 |
50 |
100 |
150 |
200 |
Internal diameter of equipment, D, mm |
2000 |
2000 |
2400 |
3000 |
3400 |
3400 |
Design pressure, MPa |
0,6; 1,0; 1,6; 2,5 |
|||||
Water content, % |
|
|||||
At the inlet, mg/dm3 |
100-1000 |
100-1000 |
100-1000 |
100-1000 |
100-1000 |
100-1000 |
At the outlet, mg/dm3 |
0,5-5,0 |