Oil/gas separators, upgraded (NGS)
An example of NGS identification for an order and other documents:
- NGS 50-1.6-T-I-P-HL1 TU 3615-003-22642986-2016,
- where 50 – volume, m3;
- 6 – design pressure, MPa;
- T – heat treatment;
- I – devices fixing heat insulation;
- P – internal anti-corrosion coating;
- HL1 – climatic design.
Upon a Client’s request, we may manufacture the upgraded oil/gas separators without an automation system.
Parameters and dimensions of equipment
Parameter | Typical dimensions | |||||
---|---|---|---|---|---|---|
NGS-A 6.3 |
NGS-A 12.5 |
NGS-A 25 |
NGS-A 50 |
NGS-A 100 |
NGS-A 150 |
|
Volume, m3 |
6,3 |
12,5 |
25 |
50 |
100 |
150 |
Internal diameter of equipment, Din, mm |
1200 |
1600 |
2000 |
2400 |
3000 |
3400 |
Capacity: |
|
|
|
|
|
|
- in terms of oil/water mixture, m3/h |
up to 20 |
up to 40 |
up to 80 |
up to 150 |
up to 120 |
up to 300 |
- in terms of gas*, nm3/h |
from 1280 up to 5490 |
from 2070 up to 7490 |
from 6400 up to 27400 |
from 12800 up to 54900 |
from 25500 up to 75000 |
from 38200 up to 109200 |
Design pressure, MPa |
0,6; 1,0; 1,6; 2,5; 4,0; 6,3 |
0,6; 1,0; 1,6; 2,5; 4,0 |
0,6; 1,0; 1,6 |
|||
Fluid temperature, °C |
from 0 to 100 |
|||||
Mass concentration of liquid in the treated gas, g/m3 |
0,1 |